EasyManua.ls Logo

Bosch Rexroth Tightening System 350 - Setting the Time on the Tightening Controller; Synchronizing Date and Time with an External Clock

Bosch Rexroth Tightening System 350
641 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 608 878 300 Tightening Technology | Bosch Rexroth AG 581/641
System 350 | 3 608 878 300/2019-03
7.5.6 Setting the time on the tightening controller
The time on the tightening controller can be set if the controller is connected to the BS350. Set the time
via System System time. Table 7–25 shows the possibilities for setting the time of the tightening
controller.
The time is logged, e. g. in the course of the tightening results output, enabling times to be assigned to
the tightening results data.
7.5.7 Synchronizing date and time with an external clock
The date and time can be manually set in the BS350. Additionally, the clock can be set automatically via
a so-called timeserver. In this case, the clock is synchronized with the timeserver clock whenever the
system is booted and periodically thereafter.
To indicate a timeserver:
1. In the BS350 operating system, click System Tightening channel configuration
2. Double click the parameter field for the compact system.
The parameter dialog Rexroth BS350 - Compact system appears.
Fig. 7–25: Configuration of time synchronization with an NTP server
3. Enter the name (or IP address) of the timeserver in the NTP server address field.
4. Assign the synchronization interval in the Sync interval field.
5. Click Accept to accept the settings.
Table 7–25: Setting the system time
Element Description
Date and time These values can be changed by directly entering numbers or by clicking the plus
or minus button. The plus or minus button changes the field that the cursor is
currently in.
System time / PC time System time: Makes it possible to set the system time.
PC time: Shows the current PC time and takes it over in the entry fields. This
time cannot be changed.
Set system time Transfer modified setting to the tightening cell.
This button is only active if no synchronization with an external clock is taking place.
Time zone Selection of the desired time zone, which is calculated from Greenwich Mean Time
(GMT) and a time shift factor.
You can also set whether the clock should automatically be changed for daylight
savings time (summer time) and winter time.
All tightening system outputs, e.g. printer or FTP, use the local time for the tightening system, taking the
time zone and, if necessary, the automatic daylight savings time change into consideration. This also
applies to outputs in the BS350 like actual values or curves. The settings of the operating system are,
however, not used! This is why there may be deviations between the PC time and the BS350 outputs.

Table of Contents

Related product manuals