EasyManua.ls Logo

Bosch Rexroth Tightening System 350 - Messages

Bosch Rexroth Tightening System 350
641 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
452/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
6.9.5 Messages
The controller messages of the VW-XML protocol are implemented as required in chapter 4.3
"Messages/SST-controller" of the VW-corporate requirement specifications. Special features for
adjusting the Rexroth Tightening System 350 are available for individual controller messages.
Channel number <KNR>
In VW-XML, the channel number is used to address certain channels explicitly.
In single-channel operation with the compact system, channel number assignment is optional. However,
it is possible to address the compact system using channel number 1.
A single tightening channel of the modular system is identified as follows:
Tool release <TOL>
In order to be able to release or disable the tool of a certain channel via VW-XML, the signal
"Enable" (En) must be applied to the "XML" PLC-module in the compact system; see table 6–137;
"Enable of the particular channel (CH x.y En) must be applied to the "XML" PLC-module in the
modular system; see table 6–138.
Loosen disable <LSN>
In order to be able to release or disable loosening of a certain channel via VW-XML, the signal
"Block Loosen" (CcwLock) must be applied to the "XML" PLC-module in the compact system; see
table 6–137.
"Block Loosen" of the particular channel (CH x.y CcwLock) must be applied to the "XML"
PLC-module in the modular system; see table 6–138.
Start <STR>
In order to be able to start the tightening spindle of a certain channel via VW-XML, the signal
"Start signal" (Cw) must be applied to the "XML" PLC-module in the compact system; see table 6–
137.
"Start signal" of the particular channel (CH x.y Cw) must be applied to the "VW-XML" PLC-module
in the modular system; see table 6–138.
Program selection <PRS>
In order to be able to select the tightening program of a certain channel via VW-XML, the signal
S for program selection (Prg0…Prg7) must be applied to the "XML" PLC-module in the compact
system; see table 6–137.
S for program selection of the particular channel (CH x.y Prg0…CH x.y Prg7) must be applied to the
"XML" PLC-module in the modular system; see table 6–138.
Group selection <GRP>
In order to be able to display and use all functions of a modular system with eight (8) application blocks
and 48 parameterizable applications VW-XML, the group number (GNR) has to be coded. If the number
of NOK group events is reached, the application block is disabled.
Group number for application block 1:
KNR Rack 6 slot+=
Example For a modular system, this assignment means that a channel in slot 3 of rack 2 is addressed using
channel number 15.
GNR Applicationnumber=

Table of Contents