522/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
7.1.2 Recommended filter intervals (gradient parameters)
In the start step of a tightening program, the calculation of the gradient values is parameterized using
gradient parameters. This is particularly important with yield-point controlled tightening processes. One
of these gradient parameters is the so-called filter interval that is used to improve suppression of output
drive-specific interferences in the gradient signal. The filter interval leads to an extended smoothing of the
gradient graph, but also delays gradient evaluation.
Information on the gradient parameters in general and on the filter interval in particular can be found in
the "Project planning" documentation of the Rexroth Tightening System 350.
The filter interval depends on the mechanical output drive component. Table 7–1 shows the filter intervals
for different output drives recommended by Rexroth.
Table 7–1: Recommended filter intervals
Designation Code Order number
Filter interval [°]
1 x 2 x
Offset output drive BG 4 VNK1A156 0 608 800 501 40
Offset output drive BG 4 VNK1C156 0 608 800 502 40
Offset output drive BG 5 VNK3C281 0 608 800 543 40
Offset output drive BG 5 VNK3C350 0 608 800 545 40
Offset output drive BG 3 VNL3C418 0 608 800 548 40
Offset output drive BG 3 VN1A102 0 608 800 592 32,72
Offset output drive BG 3 VN2A152 0 608 800 594 32,72
Offset output drive BG 3 VN2B152 0 608 800 595 32,72
Offset output drive BG 3 VN1C102 0 608 800 602 32,72
Offset output drive BG 3 VN2C152 0 608 800 603 32,72
Offset output drive BG 2 2VNA82 0 608 800 607 36
Offset output drive BG 2 2VNB82 0 608 800 608 36
Feed output drive BG 4 4S1 0 608 800 609 21,18 42,35
Feed output drive BG 3 3S1 0 608 800 610 14.4 28.8
Feed output drive BG 3 3S2 0 608 800 611 14.4 28.8
Feed output drive BG 2 2S1 0 608 800 612 18,95 37,89
Feed output drive BG 2 2S2 0 608 800 619 18,95 37,89
Offset output drive BG 3 VNS2A152 0 608 800 629 36
Offset output drive BG 3 VNS2B152 0 608 800 630 36
Offset output drive BG 3 VNS2C152 0 608 800 631 36
Offset output drive BG 3 with
measurement transducer
3VMC017 0 608 801 001 32,72
Offset output drive BG 3 with
measurement transducer
3VMC035 0 608 801 002 32,72
Offset output drive BG 3 with
measurement transducer
3VMC060 0 608 801 003 32,72
Offset output drive BG 4 with
measurement transducer
4VMC150 0 608 801 004 40
Offset output drive BG 4 with
measurement transducer
4VMC210 0 608 801 005 22.5 45
Offset output drive BG 4 with
measurement transducer
4VMC360 0 608 801 006 22.5 45
Offset output drive BG 3 with
measurement transducer
3VMC017-SD 0 608 801 012 32,72
Offset output drive BG 3 with
measurement transducer
3VMC017-QC 0 608 801 018 32,72
Offset output drive BG 3 with
measurement transducer
3VMC060-SP 0 608 801 023 32,72
Offset output drive BG 3 with
measurement transducer
3VMC060-QC 0 608 801 020 32,72
Offset output drive BG 4 with
measurement transducer
4VMC150-SD 0 608 801 015 40
Offset output drive BG 4 with
measurement transducer
4VMC150-QC 0 608 801 021 40
Offset output drive BG 4 with
measurement transducer
4VMC210-SD 0 608 801 016 22.5 45
Offset output drive BG 4 with
measurement transducer
4VMC210-QC 0 608 801 022 22.5 45

Table of Contents