6.4.4 Formats of the results output
6.4.4.1 Parameters/values in the output
Available results values for application results
The results of tightening applications are comprised of the application result (in accordance with Table
6–49) and a channel result for each participating tightening channel (in accordance with Table 3).
Available results values for single-channel tightenings and channel results within an application result
The values listed in Table 6–50 are available for the results from single-channel tightening processes and
channel results within a tightening application.
Table 6–49 shows all the possible results for a tightening application. The results to be output are defined
in the BS350 operating program (see page 301).
Table 6–49: Results values of tightening applications during output
Name Meaning Length in
bytes
Format Comments Example
FO:Application block 1 Int8 3
FO:Application Application number 1 Int8 47
FO:Application name 1-20 ASCII Filled with space
characters, if
necessary
Cylinder head 5 cyl.
FO:ID code Application ID code 1-64 ASCII TKZ 7688-A
FO:C. no. KE KE serial number 4 INT32 861000000
FO:Date Date and time 4 INT32 1098773240
1
FO:Result Application results 1 Int8 (1 or -1) 1 = OK, -1 = NOK
FO:Quality code 5 ASCII With leading space
characters, if
necessary
____1 = all OK
FO:Stopped by Switch-off criterion 2 ASCII _0
FO:Number of tightening
positions
1Int8 5
1 Date and time are indicated in seconds counted since 1. 1. 1970, 12:00:00 a.m.
The number 1098773240 corresponds to the following time: Tuesday, 10/26/2004, 6:47:20 a.m.
Table 6–50 shows all the possible results for tightenings. The results to be output are defined in the
BS350 operating system (see sections 6.4.4.4 and 6.4.4.5).
If a docu step is not run through or if the tightening channel is in bypass (see "Project planning"
documentation of the Rexroth Tightening System 350), the value 0@ will always be output as the step
number for this/these docu level(s).