524/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
7.1.3 Overview of commissioning steps
The following sections give an overview of the commissioning steps for:
• Compact system CS351 (page 524)
• Modular system 350 (page 525)
7.1.3.1 Compact system CS351
ErgoSpin ESA065S-G 0 608 841 209 13,33 26,66
ErgoSpin ESA065G-G 0 608 841 229 13,33 26,66
ErgoSpin ESA075S-G 0 608 841 210 14.4 28.8
ErgoSpin ESA075G-G 0 608 841 230 14.4 28.8
ErgoSpin ESA100S-G 0 608 841 211 13,33 26,66
ErgoSpin ESA150S-G 0 608 841 212 15,65 31,3
ErgoSpin ESA220S-G 0 608 841 213 13,33 26,66
Table 7–1: Recommended filter intervals
Designation Code Order number
Filter interval [°]
1 x 2 x
Please find information on the commissioning of the Nexo cordless Wi-Fi nutrunner and on the definition
of tightening programs in the "Nexo" documentation.
Assembling the tightening spindle (see page 525) or the ErgoSpin hand-held nutrunner (see page 526)
Assembling the compact system (see page 526)
Inserting the interface modules (see page 527)
Connecting the tightening spindle (see page 528) or the ErgoSpin hand-held nutrunner (see page 528) to the
compact system
Mains connection of the CS351 compact system (see page 529)
Switching on the tightening cell (see page 534)
Connecting the PC (see page 536)
Installing the BS350 operating system (see page 537)
Starting the BS350, setting up the programming interface, password entry (see page 538) to (page 541)
Configuring the tightening channel (see page 550) and (page 576)
Fig. 7–1: Overview of commissioning steps for compact system CS351