320/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
6.5.2 Formats of the results output
To set the desired output format:
1. In the BS350 operating system, click System Tightening cell data.
2. Click Printer 1 or Printer 2 to open the dialog to set the results output.
The System / Tightening cell data / Printer dialog will open.
Fig. 6–66: Settings for the results output on a printer
A description of the various options can be found in the following sections.
The settings for results output on a printer are made in the BS350 operating program and are separated
into output via the communication unit or the control unit.
6.5.2.1 Interface selection
Here, set the (RS232) interface with which you want to send the data to the receiving device. You
can only select interfaces that are equipped and not currently occupied by other services
1)
.
6.5.2.2 Print output
Use the print output section to set which results should be output. In the Off setting, results output
is inactive, i. e. no results will be output. This setting does not influence the results output via other
data services.
6.5.2.3 Output formats
Formats identical to those for “Results output via FTP” are available for results output (see Output formats
(page 226)). Select the suitable format for your application.
6.5.2.4 Protocol elements of the output
Output of protocol elements via printer communication is identical to output via Ethernet. A description
can be found under Protocol elements of the output (page 227).
6.5.2.5 Special cases for tightening results
The special cases during output of tightening results via printer communication are identical to output via
Ethernet. A description can be found under Special cases for tightening results (page 207).
6.5.2.6 Tightening results from several steps of a tightening process
Output of tightening results via printer communication is identical to output via Ethernet. A description
can be found under Tightening results from several steps of a tightening process (page 209).
1) Interface selection is implemented here in the operating system, but also by correctly wiring the
interface plug. Only one standard (RS232, RS422, 20mA) may be active per interface.