3 608 878 300 Tightening Technology | Bosch Rexroth AG 295/641
System 350 | 3 608 878 300/2019-03
Table 6–50: Results values of channel results during output (Section 1 of 2)
Name Meaning Length in
bytes
Format Example Name
C. no. KE Consecutive tightening number 4 INT32 861000000 C. no. KE
Application Application number 1 Int8 47 Application
Tightening
position
Name of the tightening position 1-20 ASCII Cylinder head 5
cyl.
Tightening
position
Result Evaluation of application, tightening program, or
step
1 Int8 (1 or -1) 1 = OK
–1 = NOK
Result
Quality code 5 ASCII ____1 = all OK Quality code
ID code ID code of the tightening/single-channel tightening 1-64 ASCII TKZ 7688-A ID code
Date Date and time 4 INT32 1098773240
1
Date
C. no. CS351/
SE352
Consecutive number tightening 4 INT32 185000067 C. no. CS351/
SE352
Program Program number 1 Int8 32 Program
Program name 1-20 ASCII 5 cyl. Program name
X*
2
:step 1 (line) Int8 4B X*
2
:step
1 (column) ASCII
X*:Result 1 Int8 (1 or -1) 1 = OK, -1 = NOK X*:Result
X*:Quality code 5 ASCII ____1 = all OK X*:Quality code
X*:Stopped by Switch-off criterion 2 ASCII _0 X*:Stopped by
X* etc.:T– Lower limit of the MF Torque 4 INT32 X* etc.:T–
X*:T Actual value from TF Upper torque, TF Lower
torque, and/or MF Torque
4INT32 X*:T
X*:T+ Upper limit of the MF Torque 4 INT32 X*:T+
X*:TP Programmed value of the TF Upper torque 4 INT32 X*:TP
X*:TPl Programmed value of the TF Lower torque 4 INT32 X*:TPl
X*:TV Graph value Torque 4 INT32 X*:TV
X*:A– Lower limit of the MF Angle 4 INT32 X*:A–
X*:A Actual value from TF Angle and/or MF Angle 4 INT32 X*:A
X*:T+ Upper limit of the MF Angle 4 INT32 X*:T+
X*:TTA Torque threshold Angle counting for TF A
and/or MF A
4INT32 X*:TTA
X*:AP Programmed value of the TF Angle 4 INT32 X*:AP
X*:AV Graph value Angle 4 INT32 X*:AV
X*:G– Lower limit of the MF Gradient 4 INT32 X*:G–
X*:G Actual value of the TF Gradient and/or MF Gradient 4 INT32 X*:G
X*:G+ Upper limit of the MF Gradient 4 INT32 X*:G+
X*:TTG Torque threshold for Gradient, Gradient average
value, and/or Yield point
4INT32 X*:TTG
X*:GP Programmed value of the TF Gradient 4 INT32 X*:GP
X*:Yp Actual value of the TF Yield point and/or MF Yield
point
4INT32 X*:Yp
X*:Yp+ Limit of the MF Yield point 4 INT32 X*:Yp+
X*:YpP Programmed value of the TF Yield point 4 INT32 X*:YpP
X*:t Actual value of the TF Time and/or MF Time 4 INT32 X*:t
X*:t+ Limit of the MF Time 4 INT32 X*:t+
X*:tP Programmed value of the TF Time 4 INT32 X*:tP
X*:TR Actual value of the MF Redundancy torque 4 INT32 X*:TR
X*:TR+ Limit of the MF Redundancy torque 4 INT32 X*:TR+
X*:TRT Torque threshold for MF Redundancy torque 4 INT32 X*:TRT
X*:AR Actual value of the MF Redundancy angle 4 INT32 X*:AR
X*:AR+ Limit of the MF Redundancy angle 4 INT32 X*:AR+
X*:ARS Torque threshold for MF Redundancy angle 4 INT32 X*:ARS
X*:T&– Lower limit of MF Relative torque 4 INT32 X*:T&–