290/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
6.4.1.2 Function diagram
Fig. 6–48: Function diagram of data exchange via field bus
6.4.1.3 Exchanged data
The following data can be exchanged via the interface module:
• Control signals from/to the partner controller
• ID-codes for single channels (control unit/communication unit) and for tightening applications
(communication unit)
• Tightening results from single-channel tightenings (control unit/communication unit), tightening
results from tightening applications (communication unit).
• IL data for data exchange with the integrated logic via the ControlFieldbus function block.
A description of the control signals and their applications can be found in chapter 5, Control signals, from
page 121.
Tightening results are output for each tightening process. This is why a clear identification of the
tightening results is necessary, to be able to e. g. assign archived tightening results at a later point. The
Tightening System 350 allows the identification of each tightening result record with an ID code provided
by the partner controller.
Inputs
ID code
IL data
Partner
controller
Control signals ID code IL data
EN CW CCW
ABCDXXXX EFG
1 1 0 41 42 43 44 58 58 58 58 45 46 47
IL data Angle Torque Control signals
HIJ 135,85° 101,100 Nm
CyCmp OK NOK
48 49 50 A4 BA 14 00 30 44 9A 00 1 1 0
Outputs
Results
IL data
CS351
KE350
Data exchange via the interface module can only be implemented if the data input/output field has been
configured and at least one control signal has been set.