384/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
MID 0061 revision 003
Time stamp Date and time of the tightening.
The value consists of 19 ASCII characters in the format
YYYY-MM-DD:HH:MM:SS.
ID 45
2
Value range 0 – 9, "-" and ":"
Presetting -
Example:
Time stamp 1/12/2009:2:43:57 PM
Value 1/12/2009:2:43:57 PM
19
Date/time of the last change Date and time of the last change in the tightening program settings.
The value consists of 19 ASCII characters in the format
YYYY-MM-DD:HH:MM:SS.
ID 46
2
Value range 0 – 9, "-" and ":"
Presetting -
Example:
Date/time of the
change
1/12/2009:2:43:57 PM
Value 1/12/2009:2:43:57 PM
19
Data length revision 002
365
Table 6–100: MID 0061 revision 003
Parameter Comments Bytes
This revision includes the information from revision 002 and the following additional information:
Tightening program name Fill in with empty spaces if < 25 characters.
The value consists of 25 ASCII characters.
ID 47
2
Value range 0x20 – 0x7F
Presetting -
Example:
Tightening
program name
Tightening program 3
Value Tightening program 3
25
Torque value units – 1: Nm
–2: Ftlb
–3: Inlb
–4: Kpm
– 5: Kgfm
–6: Kgm
–0: All other units
The value consists of one ASCII character.
ID 48
2
Value range 0–4
Presetting -
Example:
Torque value
units
Kpm
Value 4
1
Table 6–99: MID 0061 revision 002
Parameter Comments Bytes