3 608 878 300 Tightening Technology | Bosch Rexroth AG 437/641
System 350 | 3 608 878 300/2019-03
General tightening result parameters
Table 6–127: General tightening result parameters and their meaning
Parameter
Meaning
format The format identifier enables recognition of the type of the
transmitted JSON file by the communication partner.
channel
The received file contains the tightening results of a single
tightening channel.
application
The received file contains the data of one tightening
application.
–error
The received file contains the error codes (new entry /
acknowledgement)
date Date/time of tightening
node id ARCNET address of the tightening channel.
mac0 MAC address of the transmission unit (KE or CS)
ip0 IP address of the transmission unit (CS or KE)
channel Channel name
no. Channel number SYSTEM 200, see table 6–13 on page 230
spindle id ID number of tightening spindle
hardware Hardware code, e.g. "CS351", "SE352", "KE350",
sw version Software version
sw build Build version
action Time when the error occurred:
startup
On startup of the system, starting of the HTTP service.
–modified
During operation.
content index
Cons. no. Index number in the error list of the controller.
–code
Error code
–class
Error class
acknowledged
0 = New entry of the error
1 = Acknowledgement of the error
location name Location name
tool serial Measurement transducer serial number. In case of spindles
with redundancy transducer, the serial number of the primary
transducer is returned.
redundancy transducer serial Redundancy transducer serial number
nominal torque Admissible nutrunner torque
MCE factor MCE factor of the measurement transducer
MCE factor redundancy MCE factor of the redundant measurement transducer