6.12.4.2 Production and quality data
The PQD data record has the following structure:
The tightening results are assigned to the production point and the quality identifier via the channel
number, program number, application number and position number fields from the configuration.
6.12.4.3 Status of PLUS
The status display of PLUS comprises the following data:
6.12.4.4 Diagnosis and troubleshooting
For diagnosis, the following two options are available:
• Detailed text protocol
This protocol can be accessed via BS350 under System test Diagnosis PLUS.
• Sequence trace
The sequence trace can be accessed via BS350 under System test ... FF3 or FF4.
• BS350 error list for system errors
Print ... Output of settings via a printer or display as preview.
Load default values Loading default settings
OK Transmission of the activation of the PLUS 1.0 data protocol to the controller.
The option is only released for logged in users.
Cancel Closes the dialog window without accepting the changes
Table 6–156: Settings in BS350 for PLUS activation
Element Description
Table 6–157:
Header Data fields
FP Time,... QI Measurement values, limit values Status
QI Measurement values, limit values Status
QI Measurement values, limit values Status
Table 6–158: Status display of PLUS
Element Description
Initialization Status during/after initialization.
operating state Current status of the PLUS Protocol
From Time of status inquiry.
PLUS connection PLUS connection status
Previous communication Time of previous communication between the BS350 tightening system and the
PLUS server.
Error Number of errors.
Packages Number of the packages transferred.
Previous PLUS telegrams Displays the previous PLUS telegrams.