3 608 878 300 Tightening Technology | Bosch Rexroth AG 583/641
System 350 | 3 608 878 300/2019-03
Further functions
Stop
stops the running program prematurely.
Reset acknowledges class 3 errors.
Standard indicates the number of times the selected tightening program can be started in a row.
As of version V2.400: Wait after start... specifies the time before the sequence test is executed.
Values from 15 to 500 seconds are valid. As the time is determined at the operating system, it is
subject to tolerance.
The system status displays are activated by selecting Start, Stop or Loosen.
The system status display to the left indicates the hardware's system status:
Green: Tightening channel is ready for operation
Red: System error
The system status display to the right provides information about the last tightening job:
Green: The last tightening result is OK
Red: The last tightening result is NOK
Gray: Invalid status, i.e. tightening channel is not yet ready for operation again or no tightening job
has been performed yet
After a successful sequence test, both system status displays on the control panel and on the tightening
controller emit a static green light.