590/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
IMdev You can make the following settings in the Set up DeviceNet interface group:
No settings can be made in the Configured ranges field: The grayed out fields cannot be edited. The
parameters displayed in this field depend on the selected number of I/O points.
A participant profile in form of an EDS (electronic data sheet) file is required to commission the IMdev
interface module. The EDS file (*.eds) enables recognition of variable parameters and their value ranges
in the software.
After setting all parameters, create the EDS file by clicking Create EDS file. Save the file and import
it into the field bus configurator.
Click Accept to take over this data in the configuration for the tightening channel in the BS350.
Table 7–27: Settings in BS350 for IMdev - I/O and data
Element Description
MAC ID Media Access Code Identifier - Interface module address, address range 0 to 63
Baud rate Transmission rate of 125, 250, 500 kbit/s; in addition, the auto detection function
can be selected
Number of I points Number of control signals to be processed via the DeviceNet interface: Value range
16 to 512 input signals (2 to 64 bytes)
Number of O points Number of control signals to be processed via the DeviceNet interface: Value range
16 to 512 output signals (2 to 64 bytes)
Receive data Memory location for receiving the ID code, max. 254 bytes at 2 bytes for I points
Send data Memory location for sending results, max. 254 bytes at 2 bytes for O points
Receive IL data Memory location for receiving IL data, max. 254 bytes at 2 bytes for I points
These data are processed using the IL function block ControlFieldbus.
Send IL data Memory location for sending of IL data, max. 254 bytes at 2 bytes for O points
These data are processed using the IL function block ControlFieldbus.
Example If 16I was selected as the number of I points and 32O as the number of O points, 16 inputs (= 2 bytes)
and 32 outputs (= 4 bytes) will also be available in the field bus configurator.