3 608 878 300 Tightening Technology | Bosch Rexroth AG 623/641
System 350 | 3 608 878 300/2019-03
Table 7–40: Barcode scanner within ErgoSpin: Timing parameter
Timing
parameter
Explanation Standard value
[s]
Value range [s] Modification
step [s]
Special value [s]
Activation time
laser
Maximum
illumination time
until automatic
deactivation of the
laser
0,5…25,5 0,1 0: Continuous
operation
Release time The scanner can
be released using
the PLC signal
EnScan. The
duration is set
using this
parameter.
1…99 1 0: Scanner is
released as long
is the PLC-signal
is present.
1…99 If the
PLC-signal is
present, the
scanner is
released from the
set time.
Time acoustic
signal decode
Duration of the
acoustic signal
upon recognizing
a barcode
0,1…9,9 0,1
Delay during
continuous
operation
Only relevant if
scanner in
continuous
operation (laser
always activated)
Waiting time upon
recognizing a
barcode until the
next barcode is
recognized.
0,5…9,9 0,1