3 608 878 300 Tightening Technology | Bosch Rexroth AG 71/641
System 350 | 3 608 878 300/2019-03
Cable outlet at servo
amplifier
The cable outlet at the servo amplifier can be adjusted to individual handling preferences. Observe the
angle of turn of the plug, as shown in the following Figure.
Fig. 4–4: Cable outlet at servo amplifier
4.2.3.1 Tightening spindle
The tightening spindle is connected to the CS351 compact system or to the servo amplifier via a
connection cable.
Fig. 4–5: Connection cables for tightening spindles
The different cable types are illustrated with order numbers in the current product catalog.
NOTICE
Malfunction, damage to system
Functional safety and system safety jeopardized
Only use accessories, add-on units, and cables that have been approved for use in Rexroth
tightening systems.
On assembly, the connection cables are to be tightened by hand. A suitable tool may also be used for
assembly (pipe wrench with plastic jaws). For example, pipe wrench with plastic jaws by Knipex (article
no. 825429-62).
-152 ° +152 °
STOP
A Tightening spindle connection cable straight – angle
B Tightening spindle connection cable angle – angle
C Tightening spindle extension cable straight–straight
D Tightening spindle extension cable angle–straight
A:A:
B:
C:
D: