D9887B receiver – base unit
78-4043743-01 Rev A 207
Max Power:
200 W
Current Draw/Power:
Typical 1 Decoder with 4
option cards:
0.40 A / 50 W
Typical 2 Decoders with 8
option cards:
0.60 A / 70 W
Frequency:
47–63 Hz
Connector:
IEC C14
Line Cord:
Detachable, 6 foot, 3-prong
DC Power –
Operating Voltage:
40 – 60 VDC
Max Current Draw/Power:
4.17 A / 200 W (at 48 VDC)
Current Draw/Power:
Typical 1 Decoder with 4
option cards:
1.04 A / 50 W
Typical 2 Decoders with 8
option cards:
1.46 A / 70 W
Connector:
Tyco Amplimite 109 series 3C3
Line Cord:
Detachable, 5 ½ foot
General –
Operating Temperature:
0 to 45 degrees C
Operating Humidity:
< 95% Non-Condensing
Cooling:
Forced air, front intake, rear exhaust
Temperature monitor:
Fan failure, internal temperature sensor
Size:
Height – 1RU (1 ¾"), Width = 19", Depth = 19"
19" rack mountable, with removable ears
Rack clips and screws included
Weight:
9.5 lbs. (base unit)
12.75 lbs. (fully loaded)
Pollution Degree:
2
Installation Category:
II
Grounding Post:
On chassis