Configuring SIP, SPCP, and NAT
Configuring SIP
Cisco Small Business SPA300 Series, SPA500 Series, and WIP310 IP Phone Administration Guide 118
4
STEP 6 Click Submit All Changes.
Configuring a SIP Proxy Server
To configure SIP proxy and registration parameters:
STEP 1 Log in to the configuration utility.
STEP 2 Click Admin Login and advanced.
STEP 3 Click the Extension <number> tab.
STEP 4 Configure the proxy and registration parameters for each extension.
Voice Quality Report
Address
For configuration of a SIP event package, SIP PUBLISH, that
enables the collection and reporting of metrics that measure
the quality for VoIP sessions. Voice call quality information
derived from RTCP-XR and call information from SIP is
conveyed from a User Agent in a session to the third party in
SIP PUBLISH method.
To configure, first configure RTCP-XR (see the “Configuring
RTP Parameters” section on page 108). For example, you
need to configure the RTCP Tx Interval. In the Voice Quality
Report Address field, enter the name of the collector that will
collect the statistics from the SIP PUBLISH events. For
example, enter collector@
fully-qualified-domain-name
(collector@reports.cisco.com) or
collector
@
IP
-
address
(collector@192.168.5.1).
After RTCP-XR feature is enabled, the call status information is
updated on the Voice > Info page during an active call.
Additionally, RTCP-XR packets containing a voice metrics
block report will be sent with the interval specified in the RTCP
Tx Interval. When the call session is ended, a SIP PUBLISH with
voice metrics info is sent to the collector endpoint.
Parameter Description
Parameter Description
Proxy SIP proxy server and port number set by the service
provider for all outbound requests. For example:
192.168.2.100:6060.
NOTE Port number is optional. The default is port 5060.

Table of Contents

Other manuals for Cisco SPA303

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SPA303 and is the answer not in the manual?

Cisco SPA303 Specifications

General IconGeneral
DisplayMonochrome LCD
Lines3
SpeakerphoneYes
Headset JackYes (2.5 mm)
HandsetYes
Ethernet Ports2 x 10/100 Mbps
ProtocolSIP
PowerPower over Ethernet (PoE) or AC adapter
Audio Codec SupportG.711, G.729