170 SNMP Commands
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax
CLI\files\SNMP.fm
DELL CONFIDENTIAL – PRELIMINARY 5/15/12 - FOR PROOF ONLY
timeout seconds
—Number of seconds to wait for an acknowledgment
before resending informs. The default is 15 seconds. The parameter is
relevant only for informs. (Range: 1–300)
retries retries
—Maximum number of times to resend an inform request,
when a response is not received for a generated message. The default is 3.
The parameter is relevant only for informs. (Range: 0–255)
Command Mode
Global Configuration mode
User Guidelines
The logical key of the command is the pair (ip-address/hostname,
traps/informs, version).
When configuring snmp v1 or v2 notifications recipient the software would
automatically generate a notification view for that recipient for all the MIB.
(.For SNMPv3 the software doesn’t automatically create a user nor a notify
view. Use the commands snmp-server user, snmp-server group and snmp-
server view in Global Configuration mode to create a user, a group or a notify
group respectively.
The format of an IPv6Z address is: <
ipv6-link-local-address>%<interface-
name
>
interface-name =
vlan<integer> | ch<integer> | isatap<integer> |
<physical-port-name> | 0
integer = <
decimal-number> | <integer><decimal-number
>
decimal-number = 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9
physical-port-name = Designated port number, for example 1/0/16
If the egress interface is not specified, the default interface is selected.
Specifying interface zone=0 is equal to not defining an egress interface.
Example
The following defines a host at the IP address displayed.
console(config)# snmp-server host 1.1.1.121 abc