RMON Commands 285
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax
CLI\files\RMON.fm
DELL CONFIDENTIAL – PRELIMINARY 5/15/12 - FOR PROOF ONLY
mib-object-id
—Specifies the object identifier of the variable to be
sampled. (Valid OID)
interval
—Specifies the interval in seconds during which the data is
sampled and compared with rising and falling thresholds. (Range:
1–4294967295)
rthreshold
—Specifies the rising threshold value. (Range: 0–4294967295)
fthreshold
—Specifies the falling threshold value. (Range: 0–4294967295)
revent
—Specifies the index of the event triggered when a rising threshold
is crossed. (Range: 0–65535)
fevent
—Specifies the index of the event triggered when a falling threshold
is crossed. (Range: 0–65535)
type
{
absolute
|
delta
}—Specifies the method used for sampling the
selected variable and calculating the value to be compared against the
thresholds. The possible values are:
absolute—Specifies that the selected variable value is compared
directly with the thresholds at the end of the sampling interval.
delta—Specifies that the selected variable value of the last sample is
subtracted from the current value, and the difference is compared with
the thresholds.
startup
{
rising
|
rising-falling
|
falling
}—Specifies the alarm that may be
sent when this entry becomes valid. The possible values are:
rising—Specifies that if the first sample (after this entry becomes
valid) is greater than or equal to rthreshold, a single rising alarm is
generated.
rising-falling—Specifies that if the first sample (after this entry
becomes valid) is greater than or equal to
rthreshold
, a single rising
alarm is generated. If the first sample (after this entry becomes valid)
is less than or equal to fthreshold, a single falling alarm is generated.
fallin —Specifies that if the first sample (after this entry becomes
valid) is less than or equal to fthreshold, a single falling alarm is
generated.
owner
name
—Specifies the name of the person who configured this alarm.