EasyManua.ls Logo

Develop ineo 250 - Page 192

Develop ineo 250
770 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Field Service Ver. 1.0 Aug. 2005 11. Tech. Rep. Mode
153
bizhub 200/250/350Adjustment / Setting
11.3.2 Printer
A. Edge Erase
B. Loop Adjustment
Functions
To change the laser emission timing to adjust the width of the image area that is erased
at the leading edge, trailing edge and top and bottom.
Use When the PH unit is replaced
Adjustment
Specifica-
tion
Adjust the following erase width values so that
each falls within the following adjustment range:
Width A (Leading Edge); Width B (Trailing
Edge); and Width C (Top/Bottom).
Default setting: 4 mm
Adjustment range: 0 to 5 mm (in 1-mm incre-
ments)
The default setting for 2-sided trailing edge
erase width is “2 mm.
Adjustment
Instructions
To make the erase width (Width A, B, or C) smaller, decrease the setting value.
To make the erase width (Width A, B, or C) greater, increase the setting value.
Adjustment
Procedure
1. Call the Tech. Rep. Mode to the screen.
2. Touch the keys in this order: [Tech. Rep. Choice] [Printer] [Edge Erase].
3. Select the specific edge to be adjusted.
4. Press the Clear key and change the setting value using the 10-Key Pad.
5. Touch [END] to validate the new setting value.
4040F3C508DA
Width A
Width B
Width
C
Width
C
Functions To adjust the length of the loop formed in the paper before the Regist Rollers.
Use
When a paper skew occurs.
When a paper jam occurs.
Adjustment
Range
The default setting is “0”.
The adjustment range is -5 mm to +5 mm. (in 1 mm increments)
Adjustment
Procedure
1. Call the Tech. Rep. Mode to the screen.
2. Touch the keys in this order: [Tech. Rep. Choice] [Printer] [Loop Adjustment].
3. Select the paper source, for which the adjustment is made.
4. Press the Clear key and change the setting value using the 10-Key Pad.
5. Change the + or - sign using the Access key or * key.
6. Touch [END] to validate the new setting value.