Field Service Ver. 1.0 Aug. 2005 12. Troubleshooting
165
FK-503
Troubleshooting
12.2.4 Communication errors (RX)
Code Description Cause Remedy
Re Li Lo
33 Protocol failure in V.34
sequence
Failure in remote
machine
|
Try another remote machine.
Line failure | Try another line.
91 T1 timeout while waiting
for initial identification sig-
nal
Failure in remote
machine
|
Try another remote machine.
Line failure | Try another line.
92 Received DCN while wait-
ing for commands other
than DCN in phase B
Interruption or failure
in remote machine |
Check the status of the
remote machine and retry TX.
95 Detected low speed flag
followed by 10 sec. time-
out while waiting for detec-
tion of image signal carrier
(HMCD ON)
Failure in remote
machine
|
Try another remote system.
Line failure
|
Try another line.
96 Carrier disconnected for
15 seconds while receiv-
ing G3 image signal
Error in remote
machine
|
Ask for resending.
Failure in remote
machine
|
Try another remote machine.
Line failure | Try another line.
97 T2 timeout while waiting
for post message
T2 timeout while waiting
for DCN after receiving
last page
No response from remote
system after changing
mode (T2 timeout)
Error in remote
machine
|
Try another remote machine.
Accidental RTC detec-
tion (line failure)
|
Try another line.
98 Received DCN while wait-
ing for command other
than DCN in phase D
Interruption or failure
in remote machine |
Ask for resending.
99 Received PRI-Q as post
message (Communica-
tion is regarded as nor-
mal even with error
message)
Failure in remote
machine
|
Check the status of the
remote machine.
9A Cannot decode line cor-
rectly for 35 seconds while
receiving ECM image sig-
nal
Failure in remote
machine
|
Try another remote machine.
Line failure | Try another line.
Failure in FAX board | Replace FAX board
Failure in MFBS board | Replace MFBS board
9C Received CRP 3 times
while waiting for initial
identification signal
Failure in remote
machine
|
Try another remote machine.
Failure in FAX board | Replace FAX board
Failure in MFBS board | Replace MFBS board
Line failure | Try another line.