Field Service Ver. 1.0 Aug. 2005 11. Tech. Rep. Mode
155
bizhub 200/250/350Adjustment / Setting
F. Fuser Temp.
11.3.3 Sheet-through-ADF
A. Registration Loop
B. Zoom
C. Feed (CD)
D. Feed (FD)
Functions
To adjust the temperature of the Fusing Roller for each paper type in order to change
the fusing performance according to the operating environment and paper type.
Use
To adjust the fusing temperature for each type of paper.
When a fusing failure occurs.
When the paper type is changed.
Adjustment
Range
The default setting is “1”.
Setting Range: 1 to 4 (Normal) 1 to 3 (Thick Paper) 1 to 3 (OHP)
1 to 3 (Thin Paper)
Adjustment
Procedure
1. Call the Tech. Rep. Mode to the screen.
2. Touch the keys in this order: [Tech. Rep. Choice] [Printer] [Fuser Temp.].
3. Select the paper, for which the adjustment is made.
4. Press the Clear key and change the setting value using the 10-Key Pad
5. Touch [END] to validate the new setting value.
For more details, see the temperature table for fusing temperature adjustment.
157
Functions To adjust the length of the loop formed in the paper before the Registration Rollers.
Use
If slippage occurs due to a worn Document Take-Up Roller, which sometimes results in
misfeeds, the loop length may be increased as a temporary measure until the part can
be replaced with a new one.
Setting/
Procedure
For details on adjustment, see the Service Manual for Option DF-605.
Functions
To set the scanning zoom ratio in the main and sub scanning directions of the Sheet-
through-ADF.
Use Upon setup of the Automatic Document Feeder
Setting/
Procedure
For details on adjustment, see the Service Manual for Option DF-605.
Functions
To adjust the scan start position in the main scanning direction (CD) of the Sheet-
through-ADF.
Use Upon setup of the Automatic Document Feeder
Setting/
Procedure
For details on adjustment, see the Service Manual for Option DF-605.
Functions
To adjust the scan start position in the sub scanning direction (FD) of the Sheet-
through-ADF.
Use Upon setup of the Automatic Document Feeder
Setting/
Procedure
For details on adjustment, see the Service Manual for Option DF-605.