Field Service Ver. 1.0 Aug. 2005 11. Tech. Rep. Mode
187
bizhub 200/250/350Adjustment / Setting
(2) Date & Time Setting
(3) RAM Clear
(4) Communication Log Print
(5) Software Switch Setting
(6) Respond Timeout
Functions To set the data and time-of-day
Use Use to set or change the date and time-of-day.
Setting/
Procedure
1. Call the Tech. Rep. Mode to the screen.
2. Touch [CS Remote Care].
3. Touch [Detail Setting] to access Date & Time Setting.
4. Enter the date (month, day and year), time-of-day, and the time zone from the 10-Key
Pad.
5. Touch [Job Start] to start the clock.
Functions
To clear the following data at the Center
ID Code, Primary Setting, Date/Time Input (Time Zone), Software SW Setting and AT
Command.
Use
To be used for setting CS Remote Care.
To be used for reset the every data of the Center to default.
NOTE
If RAM Clear is selected during transmission, RAM clear processing will be
implemented at the time the transmission is completed regardless of whether it
is done properly or not.
Setting/
Procedure
The default setting is “NO”
YES “NO”
Functions To print out the Communication Log.
Use Use to output and use the Communication Log.
Setting/
Procedure
1. Call the Tech. Rep. Mode to the screen.
2. Touch [CS Remote Care].
3. Touch [Detail Setting] to access Communication Log Print.
4. Load Tray 1 or Bypass Tray with A4R or 81/2 x 11 paper.
5. When the Basic screen reappears after the Tech. Rep. mode has been exited, an out-
put of the communication log is produced.
Functions To change the CS Remote Care settings.
Use To change the settings for CS Remote Care as necessary.
Setting/
Procedure
For procedures on settings, see 180.
Functions
To set retry intervals for an e-mail transmission error.
This setting can be made only when [E-Mail] is selected in System Input.
Use To change the retry intervals for an e-mail transmission error.
Setting/
Procedure
The default setting is “30 min.
10 to 1440 min.