5. Adjustment Field Service Ver. 1.0 Aug. 2005
10
Duplex Unit/
Switchback Unit
Adjustment / Setting
9. Touch [END] to display the Registra-
tion (CD) screen.
10. Touch the [Duplex].
11. Press the Clear key and use the 10-
Key Pad to set the value.
If width A is wider than the specified
range: Enter a negative value.
If width A is narrower than the speci-
fied range: Enter a positive value.
Adjustment range: + 4.0 max. and -4.0
min.
Use the * key to switch between + and -.
12. Produce another test print and check
for width A.