11. Soft Switch List Field Service Ver. 1.0 Aug. 2005
102
FK-503
Adjustment / Setting
MODE Factory setting bit
320
Bit: 7654 3210
1111 0000
HEX:F0
Bit Feature
Logic
Description
01
7 Cassette-specified print-
ing (G3-1: Tray 1)
Cannot
print
Can print When Mode 320 Bit 0 “Cassette selec-
tion per reception port” is enabled, spec-
ify the paper tray (including Bypass Tray)
for printing if receiving by G3-1.
6 Cassette-specified print-
ing (G3-1: Tray 2)
Cannot
print
Can print
5 Cassette-specified print-
ing (G3-1: Tray 3)
Cannot
print
Can print
4 Cassette-specified print-
ing (G3-1: Tray 4)
Cannot
print
Can print
3 Cassette-specified print-
ing (G3-1: Bypass Tray)
Cannot
print
Can print
0 Cassette selection per
reception port
Disable Enable Specify a cassette for printing received
documents per communication line.