Field Service Ver. 1.0 Aug. 2005 11. Soft Switch List
115
FK-503Adjustment / Setting
NOTE
• The features with (*) are settable by users. *: Screen setting
MODE Factory setting bit
370
Bit: 7654 3210
1111 1111
HEX:FF
Bit Feature
Logic
Description
01
7 Additional number of
times to retry E-mail
transmission (Network
function)
Bit 7-0: 00000000 0 Specify additional retrial
times after retrying the
number of times speci-
fied by the user.
“0” indicates no addi-
tional retrial.
Retrial operations will
end after retrying E-mail
transmissions the cur-
rent number of times
specified by the user.
6 00000001 1
5|
4
11111111 255
3
2
1
0
MODE Factory setting bit
371
Bit: 7654 3210
0100 0000
HEX:40
Bit Feature
Logic
Description
01
7 Retry interval for “number
of times to retry addi-
tional E-mail transmis-
sion” (Network function)
Bit 7-5: 000 10 min
6 001 15 min
5
010 20 min
011 25 min
100 30 min
Others Not available
1 Binary Division *
OFF ON
0 Page Division *
OFF ON