Field Service Ver. 1.0 Aug. 2005 11. Soft Switch List
151
FK-503Adjustment / Setting
NOTE
The features with (*) are settable by users. *: Screen setting of IT Series Agent
NOTE
The features with (*) are settable by users. *: Screen setting of IT Series Agent
MODE Factory setting bit
464
Bit: 7654 3210
1000 1100
HEX:8C
Bit Feature
Logic
Description
01
7 Select RAW port number
(last 8 bits). *
Bit 7-0: 00000000 Not available
6|
5
10001100 9100
4|
3 11111111 65535
2
1
0
MODE Factory setting bit
465
Bit: 7654 3210
0010 0011
HEX:23
Bit Feature
Logic
Description
01
7 Select RAW port number
(first 8 bits). *
Bit 7-0: 00000000 0 Most significant bit for
mode 464
6|
5
00100011 9100
4|
3 11111111 65535
2
1
0