Programming
Service Instructions 755 A/756 A - 00.0 - 02/2019 389
Adjust needle transport
 The display switches to Adjust needle transport.
Fig. 355: Adjust needle transport
To adjust the needle transport:
1. Press the button.
2. Enter the desired correction value using the numeric keypad.
 The needle bar moves to the specified position.
3. Keep correcting the value until the needle pierces exactly in the center
of the throat plate cutout.
Symbol Meaning
Correction of the needle transport reference position.