Programming
392 Service Instructions 755 A/756 A - 00.0 - 02/2019
Middle knife correction upper/lower position, height
of stroke
Fig. 358: Middle knife correction upper/lower position, height of stroke
Information
The arrows in the left half of the display indicate the correction direction:
Correction upward (middle knife less deep)
Correction downward (middle knife deeper)
The values produced by the test are used as reference values for all
programs.