Programming
414 Service Instructions 755 A/756 A - 00.0 - 02/2019
PWM test
 The display switches to PWM test.
Fig. 379: PWM test
The PWM test is used to test the assemblies.
To carry out the PWM test:
1. Press the desired button.
2. Enter the desired values using the numeric keypad.
3. Confirm with OK.
Symbols Meaning
PWM test On/Off
Select channel
• 1: clamp pressure programmable
• 2: not assigned for 755 A/756 A
• 3: Tape cutting
• 4: Press on/loosen tape
• 5: not assigned for 755 A/756 A
• 6: not assigned for 755 A/756 A
Enter modulation (signal strength)
• 0 - 100 %