Programming
Service Instructions M-TYPE DELTA - 00.0 - 12/2019 133
Pre-tension
Setting of the pretension during thread
cutting.
Value range
On/Off
Pre-tension
only visible if
Pre-tension is
activated
A value of 0 is
recommended as the
pretension is generated
by a mechanical tension.
Value range
00–99[%]
Delay time
only visible if
Pre-tension is
activated
The needle thread
tension remains closed
for a defined period of
time after thread cutting
and prevents the needle
thread from being pulled
further when the sewing
material is removed.
Without a thread
trimmer, this menu item
should be set to a very
low value.
Value range
0.1-7.5 [s]
Tension close by
needle movement
only visible if
Pre-tension is
activated
With this function, the
needle thread tension is
activated when sewing
start is done with jog dial
or via single stitch
button.
Value range
On/Off
Icon Menu items Value range