Programming
Service Instructions M-TYPE DELTA - 00.0 - 12/2019 127
19.4.2 Setting the Needle thread clamp parameters
Various settings can be made for the thread clamp. The possibilities are
explained in more detail in the table.
Icon Menu items Value range
Needle thread clamp • Value range
On/Off
Mode
Various modes (1 to 10) are available;
explanations can be found in the
Parameter list
• Value range
1-10
Material thickness
compensation
• Value range
On/Off
Thread clamp angle
Position for lifting/lowering the sewing
feet to release a thread jammed
underneath.
On
• Value range
000 - 359
Off
• Value range
000 - 359
Sewing foot lift angle
On
• Value range
000-359
Off
• Value range
000-359
Height
• Value range
01.0 – 12.0 [mm]
PrePressure
• Value range
01-20
PreStroke
• Value range