Programming
Service Instructions M-TYPE DELTA - 00.0 - 12/2019 147
19.4.18 Setting the Seam segment mode parameters
Various settings can be made for the segment length. The possibilities are
explained in more detail in the table.
19.4.19 Setting the Threading mode parameters
Various settings can be made for the threading mode. The possibilities are
explained in more detail in the table.
19.4.20 Setting the Operation lock parameters
Various settings can be made for the operation lock. The possibilities are
explained in more detail in the table.
Icon Menu items Value range
Length
Length =
Seam sections are measured via the
length specification (in mm)
Stitch count =
Seam sections are measured via the stitch
count
• Value range
Length/stitch count
Icon Menu items Value range
Sewing foot lift
Down =
The sewing foot is lowered in threading
mode.
Up =
The sewing foot is lifted in threading mode.
Pedal related =
The sewing foot can be lifted or lowered
with the pedal in threading mode.
• Value range
Down/
Up/
Pedal related
Icon Menu items Value range
Mode
Sewing feet remain at their last position
and cannot be moved by the user (Off) or
can be lifted using the pedal (On).
• Value range
On/Off
Stitch length
Manual stitch length adjustment with active
operation lock
• Value range
On/Off
All Inputs
All inputs active during machine blockage.
• Value range
On/Off