Programming
156 Service Instructions M-TYPE DELTA - 00.0 - 12/2019
Function module output 3
Function module output 4
Function module output 5
Function module output 6
Function module output 7
Function module output 8
•2
nd
edge Guide Height
Clean SSD
19.5 Setting Program defaults
Customer-specific settings can be made here, which are automatically
used as preset values for the first seam section during the creation of a
new program. Select the values so that they can be retained for as many
programs as possible.
Menu items in the Program defaults
Icon Menu item Value range
Stitch length
Default value
Value range
00.0 - 12.0
(depending on sewing
equipment and
subclass)
Sewing foot pressure
Default value
Value range
01 - 20
Needle thread tension
Default value
Value range
01 - 99 [%]
Sewing foot stroke Value range
0.5 - 9.0 [mm]
Bartack at seam begin Value range
On/Off
Bartack at seam end Value range
On/Off
Thread trimmer Value range
On/Off