Programming
Service Instructions M-TYPE DELTA - 00.0 - 12/2019 145
19.4.15 Setting the Material thickness detection parameters
Various settings can be made for the material thickness detection.
The possibilities are explained in more detail in the table.
Min. gap
Smallest possible gap between the sewing
foot and the edge guide.
The smallest possible distance depends
on the sewing equipment and MUST be
adapted after a change of the sewing
equipment.
• Value range
01.0 - 36.0 [mm]
Speed (Height)
Travel speed of the edge guide for the
height
only visible if the
2-axis edge guide has
been selected
• Value range
5000 - 60000 [Hz]
Min. Height
Smallest possible distance between throat
plate and edge ruler / roller
only visible if the
2-axis edge guide has
been selected
• Value range
0.1 - 12 [mm]
Icon Menu items Value range
Icon Menu items Value range
Material thickness detection • Value range
On/Off
Hysterese
Tolerance at which the material thickness
detection based on the 2
nd
stitch length,
the 2
nd
needle thread tension and/or the
2
nd
sewing foot stroke switches back.
This tolerance is designed to ensure that
there is no constant alternating between
activation and deactivation in the boundary
range.
• Value range
0.0–2.0[mm]
Pressure compensation
With extremely thick material, the foot
pressure increases above the standard set
value due to the material thickness.
To a certain extent, the machine can
compensate itself for the influence of thick
material.
only visible if Material
thickness detection is
active
• Value range
On/Off