19.4.10 Setting the Holding force parameters
Various settings can be made for the holding force of the motor.
The possibilities are explained in more detail in the table.
Bobbin rotation monitor
Value range
On/Off
Length
Seam length before the
bobbin rotation monitor
starts.
Value range
000 255 [mm]
Remaining thread monitor limit Value range
0.0-4.0
Values only apply to
the remaining thread
monitor, not the SSD.
Remaining thread monitor
intensity
Value range
0.0-4.0
Values only apply to
the remaining thread
monitor, not the SSD.
Icon Menu items Value range
Icon Menu items Value range
Mode Holding Position
Value range
On/Off/Holding
Position
Holding Position: the
sewing motor is always
regulated to this
position. It is not
possible to change the
position by using the
handwheel or setting
additional parameters.
Max. Current
Holding current of the motor
only visible if the
parameter is activated
Value range
00 - 50
Response
Response time for the continuous current
only visible if the
parameter is activated
Value range
000 - 100

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DURKOPP ADLER D867 M-Type Delta and is the answer not in the manual?

DURKOPP ADLER D867 M-Type Delta Specifications

General IconGeneral
BrandDURKOPP ADLER
ModelD867 M-Type Delta
CategorySewing Machine
LanguageEnglish

Related product manuals