EasyManuals Logo

DURKOPP ADLER D867 M-Type Delta User Manual

DURKOPP ADLER D867 M-Type Delta
250 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #137 background imageLoading...
Page #137 background image
Programming
Service Instructions M-TYPE DELTA - 00.0 - 12/2019 135
Speed limitation sewing foot
stroke
Sewing speed
As from the set value of
the Min. Sewing
foot stroke, the
speed is reduced down
to the desired value for
the Max. Sewing
foot stroke.
Value range
0050 - 3800 [rpm],
depending on
subclass
Min. Sewing foot
stroke
Sewing foot stroke at
which the speed
reduction is initiated.
Value range
00.0 - 09.0
Max. Sewing foot
stroke
Sewing foot stroke at
which the reduced
speed is reached.
Value range
00.0 - 09.0
Icon Menu items Value range