586 Eos Apex, Eos Ti, Gio, Gio @5, Ion Xe, Ion Xe 20, and Element 2 User Manual
Actions
Cues, macros, and submasters can all be triggered from analog inputs (contact closure or
analog voltage above 6.67V) or
sACN Input
.
Cues
Execute the cue with its programmed cue timing.
Create an event where an input on address 2 will fire cue 11.
Analog input:
<Event> [4] [/] [1] {Address} [2] [Cue] [1] [1] [Enter]
sACN input:
<Event> [4] [/] [1] {sACN} [2] [Cue] [1] [1] [Enter]
Macros
Triggers the macro and begin execution immediately.
Create an event where an input on address 3 will fire macro 1.
Analog input:
<Event> [4] [/] [1] {Address} [3] [Macro] [1] [Enter]
sACN input:
<Event> [4] [/] [1] {sACN} [3] [Macro] [1] [Enter]
Submasters
There are four modes: On, Off, Bump, and Fader.
On
The submaster will act as if the bump button was pressed and held down. This will toggle, or
release the same state, when activated again.
Create an event where an input on address 4 will set Sub 1 to On.
Analog input:
<Event> [4] [/] [1] {Address} [4] [Sub] [1] {On} [Enter]
sACN input:
<Event> [4] [/] [1] {sACN} [4] [Sub] [1] {On} [Enter]
Off
Used to release the submasters bump button when triggered from a Sub On action elsewhere
in a show control action
Create an event where an input on address 5 will set Sub 1 back Off.
Analog input:
<Event> [4] [/] [1] {Address} [5] [Sub] [1] {Off} [Enter]
sACN input:
<Event> [4] [/] [1] {sACN} [5] [Sub] [1] {Off} [Enter]