Show Control 587
Bump
Acts as if the input is directly controlling the bump button. If the submaster is set to have a
dwell time of Man (manual), then it will instantly flash and turn back off. It is generally
recommended to set the submaster to have a dwell time of Hold or a specified time. The first
trigger will turn the submaster On. If the submaster is set to a dwell time of Hold, the second
trigger will turn the submaster Off.
Create an event where an input on address 6 will bump Sub 1.
Analog input:
<Event> [4] [/] [1] {Address} [6] [Sub] [2] {Bump} [Enter]
sACN input:
<Event> [4] [/] [1] {sACN} [6] [Sub] [2] {Bump} [Enter]
Fader
Acts as if the input is directly controlling the fader on the submaster. A contact closure will
move the fader from 0 to 100% instantly. A 0-10VDC input will fade the value proportionally,
where 0VDC is the fader at 0%, and 10VDC is the fader at 100%.
Create an event where an input on address 7 will control the fader for Sub 3.
Analog input:
<Event> [4] [/] [1] {Address} [7] [Sub] [3] {Fader} [Enter]
sACN input:
<Event> [4] [/] [1] {sACN} [7] [Sub] [3] {Fader} [Enter]