626 Eos Apex, Eos Ti, Gio, Gio @5, Ion Xe, Ion Xe 20, and Element 2 User Manual
OSC Method Arguments Examples/Comments
/eos/cue/<list number>/<cue number>
Number of cue part
to select (in the
specified cue list and
cue number)
/eos/cue/1/1.5=2
Run Cues
/eos/cue/fire Number of cue to run /eos/cue/fire=1
/eos/cue/<cue number>/fire
Number for button
edge: 1.0=down,
0.0=up (optional)
/eos/cue/1.5/fire
/eos/cue/<list number>/<cue
number>/fire
Number for button
edge: 1.0=down,
0.0=up (optional)
/eos/cue/1/1.5/fire
/eos/cue/<list number>/<cue
number>/<part number>/fire
Number for button
edge: 1.0=down,
0.0=up (optional)
/eos/cue/1/1.5/2/fire
Cue Information Sent by Eos – see
Implicit OSC Output (on page630)
for more information
/eos/out/active/cue/<list>/<cue>
Float argument with
percent
complete0.0=started,
1.0 complete
/eos/out/active/cue/5/1=0.75
Updated once per second
/eos/out/active/cue
Float argument with
percent
complete0.0=started,
1.0 complete
/eos/out/active/cue=0.75
Updated once per second
/eos/out/active/cue/text
String argument with
descriptive text about
active cue
/eos/out/active/cue/text=
“1/1 Label 5.00 100%”
/eos/out/pending/cue/<list>/<cue> None /eos/out/pending/cue/5/1.5
/eos/out/pending/cue/<list>/<cue>/tex
t
String argument with
descriptive text about
active cue
/eos/out/pending/cue/text=
“1/1.5 Label 5.00”
/eos/get/setup
Gets default cue
times