628 Eos Apex, Eos Ti, Gio, Gio @5, Ion Xe, Ion Xe 20, and Element 2 User Manual
OSC Method Arguments Examples/Comments
channel
/eos/out/xyz
Current position of selected
channel
/eos/cmd
Channel number, XYZ_Format Enable#,
XYZ_Format Disable#
/eos/cmd=Chan 1 XYZ_Format
Enable#
/eos/cmd=Chan 1 XYZFormat
Disable#
Enables or disables XYZ
formatting for Channel 1
Note:
OSC XYZcoordinates are measured in decimal meters, regardless of the unit
selected in Setup >System Settings >Augment3d.
OSCStaging Mode
OSCMethod Arguments Examples/Comments
/eos/key/staging_
mode
Send once to activate Staging Mode. Send again to clear
Staging Mode.
OSCOther Targets - Selection
OSC Method Arguments Examples/Comments
/eos/curve number of curve to select /eos/curve=1
/eos/fx number of effect to select /eos/fx=1
/eos/snap number of snapshot to recall /eos/snap=1
/eos/pixmap number of pixel map to select /eos/pixmap=1
OSCUser
Use this command to set the OSC user ID. User 0 represents the background user (used in
Background macros and elsewhere). User -1 represents the current user on the console
receiving OSC commands.
OSC Method Arguments Examples/Comments
/eos/user number for OSC user ID
/eos/user=1
(set OSC user ID to 1)
/eos/user=-1
(set OSC user to match con-
sole)
/eos/user=0
(set OSC user as background
user)
Current User ID Output – see
Implicit OSC Output (on page630)
for more information
/eos/out/user
number for current OSC user
ID
/eos/out/user=1