EasyManua.ls Logo

Europlex 3GS - Page 177

Default Icon
386 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3GS Technical Manual
Issue 05 April 2005
Programming Menus 8-62
Standard 3GS Panel alarm events are assigned SIA codes according to the following table. The Address Field Column
relates to the Zone number or User number etc responsible for causing the Alarm event, e.g. SIA code “BA5” refers to a
Burglary Alarm on Zone 5.
SIA Code
Short
Description
3GS Panel Description Address Field
AR
AC Restoral AC Mains power restored Unused
AT
AC Trouble AC Mains power fault Unused
BA
Burglary Alarm Burglary Zone Violated while armed Zone Number
BB
Burglary Bypass Burglary Zone inhibited or disabled Zone Number
BR
Burglary Restoral Alarm/Trouble condition on zone has been
eliminated (Transmitted when System is
Unset/Disarmed)
Zone Number
BT
Burglary Tamper Short or disconnect on alarm zone Zone Number
BU
Burglary Un-Bypass Zone inhibit/disable removed Zone Number
BV
Burglary Verified 2nd Burglary zone activated causing Veri-
fied Alarm
Zone Number
CG
Close Area System has been Part Set/Armed Unused
CG1-CG30
Close Area 1-30 Block Areas 1-30 have been Set/Armed User Number
CI
Fail to Close System/Area Fail to Set due to open zone
or Service required etc.
Unused
CL
Closing Report System has been Fully Set/Armed User Number
CT
Late to Open System not disarmed on Time – Entry time-
out.
Unused
DF
Door Forced Door opened without valid access request
(Transmitted when door is forced open)
Door Number
DH
Door Left Open
Restoral
Door that had been left open is now
Restored
Door Number
DN
Door Left Open (
Non alarm, non-
trouble)
Door Left Open after “Door Open” time
expired
Door Number
DR
Door Restoral Door left open/Trouble condition elimi-
nated (Transmitted when door is closed
after being forced open or left open)
Door Number
EJ
Expansion Device
Tam p er Re s tore
Node Tamper Restored Node number

Table of Contents

Other manuals for Europlex 3GS