Programming Menus 8-75
.
Default = 255 (all access events).
System ID
This is used for distinguishing between panels during polling when multiple units are connected to a single serial line. Valid
values for a SYSTEM ID are from 0 to 127 inclusive.
Set to 0 for a remote printer set up. When using the system in auto-dial modem configuration, SYSTEM ID is usually set to
a fixed value for all panels (for example, 1).
Access control
This variable determines the level of control available to the remote user over a particular panel. Changing this value
impacts the level of control available to remote users. See the ESCO Protocol documents for details.
Dial mode
Decides if the panel will dial out and if so when. Also controls communications mode. The legal values are:
0 Direct connect.
1 Dump log data when available to a remote device.
2 Dump log data to a remote device when variable%’ is set from the panel – for example, by time command.
3 Remote Communications. Allowed based on dial access. The panel dials the programmed modem telephone
numbers when data has been logged.
Important If a DM1200 Digital Communicator is connected, the Dial Mode must be set to 0. If another communications
device such as a modem is in use, set Dial Mode to 3.
Dial Access
This option controls the access code requirement.
0: Unrestricted access. No access code required.
Access Log Filter
Log Type Description
1 Door Event
2Card Event
3 Access Node Event
4Access Exception
5 Time Zone Change (state=0=nor-
mal, 1=free access, 2=locked
6 Control Door Event
7 Access User Select, Accept, Denied
8 Log Card Select, Accept, Denied

Table of Contents