DMP 128 FlexPlus • Remote Control and Configuration 140
Command ASCII command
(host to device)
Response
(device to host)
Additional description
Player File Management
Set file to slot
association
EAX6^*X6%CPLY} CplyAX6^*X6%]
Clear file to slot
association
EAX6^*•CPLY} CplyAX6^*•]
View file to slot
association
EAX6^CPLY} X6%]
Player Commands
Start playback on a
specific player
EX6^*1PLAY} PlayX6^*1]
Stop playback on a
specific player
EX6^*0PLAY} PlayX6^*0]
Player status
EX6^PLAY} X6*]
Set player repeat
EM X6^*X6&CPLY} CplyMX6^*X6&]
Turning off repeat during
playback will stop playback
after current playthrough.
Get player repeat status
EM X6^CPLY} X6&]
Playthrough finished Unsolicited
Play
X6^*0]
Macro Commands
Run macro
ERX6(MCRO} McroRX6(]
Kill macro
EKX6(MCRO} McroKX6(]
Get macro status
ESX6(MCRO} X7)]
Set macro name
EAX6(*X7!MCRO} McroAX6(*X7!]
Get macro name
EAX6(MCRO} X7!]
Set power-on macro
EPX6(MCRO} McroPX6(] Using 0 for X6( clears
power-on macro
assignment.
Get power-on macro
EPMCRO} X6(]
Asynchronous Macro Responses
Macro started
McroSTARTED
X6(]
Macro finished
McroFINISHED
X6(]
Macro failed
McroFAILED
X6(*X7)]
Macro killed
McroKILLED
X6(*X7)]
KEY:
X6%
= Audio file name Valid characters are A-Z, a-z, 0-9, _
X6^
= Player ID 1 through 8
X6&
= Repeat status 0 = Play once, 1 = Repeat
X6*
= Play state 0 = Stopped, 1 = Playing
X6(
= Macro number 1 through 64. Response will be padded with a leading 0.
X7)
= Macro status 0 = Macro idle
X7!
= Macro name 24 characters maximum (A-Z, a-z, 0-9, and “-”)