DMP 128 FlexPlus • Remote Control and Configuration 141
Command ASCII command
(host to device)
Response
(device to host)
Additional description
Dante Control and Configuration
The following commands configure the DMP 128 FlexPlus to listen for and pass through SIS commands meant for
Extron AXI 02 AT, AXI 22 AT, and AXI 44 AT endpoints.
NOTE: The DMP must be set to Verbose mode 2/3 when using the Dante Control and Configuration
commands.
Get available remote
devices
EA EXPR} X&]X&]...]]
Verbose 2/3:
ExprAX&]
X&]...]]
Enable remote
connection for listening
ECX&*X2@EXPR}
Verbose 2/3:
ExprC
X&*X2@]
(All listening disabled when
Dante module rebooted)
Read remote
connection listening
status
ECX&EXPR} X2@]
Verbose 2/3:
ExprCX&*X2@]
Get remote devices we
are listening to
EL EXPR} X&]X&]...]]
Verbose 2/3:
ExprL
X&]
X&]...]]
Send command to
remote device
{dante@
X&:<SIS>}}
Verbose 2/3:
{dante@X&}<SIS>]
KEY:
X&
= Dante Device Name Device names are not case sensitive
X2@
= Extron Remote Connection
Mode
0 = Disabled
1 = Enabled
PRELIMINARY