EasyManuals Logo

Extron electronics DMP 128 FlexPlus User Manual

Extron electronics DMP 128 FlexPlus
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #150 background imageLoading...
Page #150 background image
DMP 128 FlexPlus • Remote Control and Configuration 141
Command ASCII command
(host to device)
Response
(device to host)
Additional description
Dante Control and Configuration
The following commands configure the DMP 128 FlexPlus to listen for and pass through SIS commands meant for
Extron AXI 02 AT, AXI 22 AT, and AXI 44 AT endpoints.
NOTE: The DMP must be set to Verbose mode 2/3 when using the Dante Control and Configuration
commands.
Get available remote
devices
EA EXPR} X&]X&]...]]
Verbose 2/3:
ExprAX&]
X&]...]]
Enable remote
connection for listening
ECX&*X2@EXPR}
Verbose 2/3:
ExprC
X&*X2@]
(All listening disabled when
Dante module rebooted)
Read remote
connection listening
status
ECX&EXPR} X2@]
Verbose 2/3:
ExprCX&*X2@]
Get remote devices we
are listening to
EL EXPR} X&]X&]...]]
Verbose 2/3:
ExprL
X&]
X&]...]]
Send command to
remote device
{dante@
X&:<SIS>}}
Verbose 2/3:
{dante@X&}<SIS>]
KEY:
X&
= Dante Device Name Device names are not case sensitive
X2@
= Extron Remote Connection
Mode
0 = Disabled
1 = Enabled
PRELIMINARY
PRELIMINARY

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extron electronics DMP 128 FlexPlus and is the answer not in the manual?

Extron electronics DMP 128 FlexPlus Specifications

General IconGeneral
BrandExtron electronics
ModelDMP 128 FlexPlus
CategoryComputer Hardware
LanguageEnglish

Related product manuals