Parameter: <timer-value> is the value for GARP leaveall timer, the valid range is 100 to
327650 ms.
Command mode: Global Mode.
Default: The default value for leaveall timer is 10000 ms.
Usage Guide: When a GARP application entity starts, the leaveall timer is started at the
same time. When the leaveall timer is over, the GARP application entity will send a
leaveall message. Other application entities will cancel all property information for that
application entity, and the leaveall timer is cleared for a new cycle.
Example: Set the GARP leaveall timer value to 50000 ms.
Switch(config)#garp timer leaveall 50000
10.1.7 name
Command: name <vlan-name>
no name
Function: Specify a name, a descriptive string, for the VLAN; the no operation of the
command will delete the name of the VLAN.
Parameters: <vlan-name> is the specified name string.
Command Mode: VLAN Configuration Mode.
Default: The default VLAN name is vlanXXX, where xxx is VID.
Usage Guide: The switch can specify names for different VLANs, making it easier for
users to identify and manage VLANs.
Examples: Specify the name of VLAN100 as TestVlan.
Switch(Config-Vlan100)#name TestVlan
10.1.8 private-vlan
Command: private-vlan {primary | isolated | community}
no private-vlan
Function: Configure current VLAN to Private VLAN. The ―no private-vlan‖ command
cancels the Private VLAN configuration.
Parameter: primary set current VLAN to Primary VLAN, isolated set current VLAN to
Isolated VLAN, community set current VLAN to Community VLAN.
Command Mode: VLAN mode
Default: Private VLAN is not configured by default.
Usage Guide: There are three Private VLANs: Primary VLAN, Isolated VLAN and
Community VLAN. Ports in Primary there are three Private VLANs: Primary VLAN,
Isolated VLAN and Community VLAN can communicate with ports of Isolated VLAN and