372
enable
dir
show ftp
41.10 show logging buffered
Command: show logging buffered [level {critical | warnings} | range <begin-index>
<end-index>]
Function: This command displays the detailed information in the log buffer channel. This
command is not supported on low end switches.
Parameter: level {critical | warnings} means the level of critical information.
<begin-index> is the index start value of the log message, the valid range is 1-65535,
<end-index> is the index end value of the log message, the valid range is 1-65535.
When only display logging buffered information of the line card must be added range
parameter, but the main control has not the request.
Command Mode: Admin and Configuration Mode.
Default: No parameter specified indicates all the critical log information will be displayed.
Usage Guide: Warning and critical log information is saved in the buffer zone. When
displayed to the terminal, their display format should be: index ID time <level> module ID
[mission name] log information.
Example 1: Display the critical log information in the log buffer zone channel and related
to the main control with index ID between 940 and 946.
Switch#show logging buffered level critical range 940 946
Example 2: Display all the information which level is warning in the log buffer zone
channel.
Switch#show logging buffered level warning
41.11 show memory
Command: show memory [usage]
Function: Display the contents in the memory.
Parameter: usage means memory use information.
Command mode: Admin Mode
Usage Guide: This command is used for switch debug purposes. The command will
interactively prompt the user to enter start address of the desired information in the
memory and output word number. The displayed information consists of three parts: