387
44.2 Commands for PoE Monitoring and Debugging
44.2.1 Monitoring and Debugging Information
44.2.1.1 show power inline
Command: show power inline
Function: Display global PoE configurations and status.
Parameters: None.
Command Mode: Admin Mode.
Default: None.
Usage Guide: The meaning of each field are listed in the following table:
The global PoE status: enabled or disabled
The global max value of available power
The global value of used power
The global value of remaining power
The global threshold of under-voltage
The global threshold of over-voltage
The power priority policy status: enabled or disabled
The non-standard PD detection status: enabled or disabled
The PD disconnection mode
The hardware version of the PoE module
The software version of the PoE module
Power supply mode
Signal: power supply over signal cables(Alternative A)
spare: power supply over spare cables(Alternative B)
Examples: Display the current global PoE status
Switch#show power inline
Power Inline Status: On
Power Available: 130 W
Power Used: 0 W
Power Remaining: 130 W
Min Voltage: 44 V
Max Voltage: 57 V
Police: Off
Legacy: Off
Disconnect: Ac