53
Switch(config)#no snmp-server enable traps
1.4.14 snmp-server engineid
Command: snmp-server engineid <engine-string>
no snmp-server engineid
Function: Configure the engine ID; the ―no" form of this command restores to the default
engine ID.
Command Mode: Global mode
Parameter: <engine-string> is the engine ID shown in 1-32 digit hex characters.
Default: Default value is the company ID plus local MAC address.
Usage Guide: None
Example: Set current engine ID to A66688999F
Switch(config)#snmp-server engineid A66688999F
Restore the default engine ID
Switch(config)#no snmp-server engineid
1.4.15 snmp-server group
Command: snmp-server group <group-string> {NoauthNopriv | AuthNopriv |
AuthPriv} [[read <read-string>] [write <write-string>] [notify <notify-string>]]
[access {<num-std>|<name>}] [ipv6-access {<ipv6-num-std>|<ipv6-name>}]
no snmp-server group <group-string> {NoauthNopriv | AuthNopriv |
AuthPriv} [access {<num-std>|<name>}] [ipv6-access
{<ipv6-num-std>|<ipv6-name>}]
Function: This command is used to configure a new group; the ―no‖ form of this
command deletes this group.
Command Mode: Global Mode
Parameter: <group-string> group name which includes 1-32 characters
NoauthNopriv Applies the non recognizing and non encrypting safety level
AuthNopriv Applies the recognizing but non encrypting safety level
AuthPriv Applies the recognizing and encrypting safety level
read-string Name of readable view which includes 1-32 characters
write-string Name of writable view which includes 1-32 characters
notify-string Name of trappable view which includes 1-32 characters
<num-std> is the access-class number for standard numeric ACL, ranging
between 1-99;
<name> is the access-class name for standard ACL, the character string