Error Message Incorrect input! Use 'no sntp server
<ipaddress/ipv6address/domain-name> <addresstype>'.
Explanation Incomplete command for this function.
Recommended Action Use complete command ‘no sntp server
<ipaddress/ipv6address/domain-name> <addresstype>'.
Error Message The address type should either 'dns' or 'ipv4 , ipv6’.
Explanation Wrong address type for sntp server setting.
Recommended Action The address type should either 'dns' or 'ipv4 , ipv6’.
Error Message Incorrect input! Use 'calendar set <mm/dd/yyyy> <hh:mm:ss>'
Explanation User input incomplete command .
Recommended Action Use 'calendar set <mm/dd/yyyy> <hh:mm:ss>'
Error Message Incorrect input! Use 'sntp clock timezone <name> <hours>
<minutes> [before-utc |after-utc]'
Explanation User input incomplete command.
Recommended Action Use 'sntp clock timezone <name> <hours> <minutes>
[before-utc |after-utc]'
Error Message SNTP time zone name must contain alphanumeric characters
only.
Explanation User input non-alphanumeric characters for time zone name.
Recommended Action Use alphanumeric characters for SNTP time zone name.